U90 Ladder 6.1.0a Features          Document version: 12/3/09

 

New I/O Expansion Modules 

Now supported by U90 Ladder: XL series I/O modules, offering more I/Os in less space. EX modules offer a built-in adapter, replacing the need for an EX-A1 adapter. Supported modules:

  • EX-D16A3-RO8
  • EX-D16A3-TO16
  • IO-D16A3-RO16
  • IO-D16A3-TO16

Jazz Models

Now supported by U90 Ladder

  • JZ10-11-UN20
  • JZ10-11-UA24

Cold Start SI

To cause PLC restart:

  • With initialization, set  SI 140 to -32500
  • Without initialization, set  SI 140 to-32000.

Slovakian support

 

To change the U90 Ladder interface language, select View>Language and click on the desired language.

Updated help files

 

Enfora GSM modem

Better support for Enfora GSM modem in U90Ladder and OS

 

 

 

U90 Ladder 5.2.6 Features     

 

Supports new Jazz model JZ10-11-PT15

New model has 3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay,1 pnp/npn Outputs.

 

 

U90 Ladder 5.2.4 Features     

 

Download via RS485 network

Specify a single controller or range of controllers at download.

 

U90 Ladder 5.2.3 Features          Document version: 16/08/07

 

Telestar GSM modem

Now supported by U90 Ladder.

Jazz: Keypad Entry

The number of Keypad Entry Variables that include Set Limits has been increased to 16—Jazz only.

Jazz: List variables

The memory capacity for variables has been increased to 3K—Jazz only.

 

U90 Ladder 5.10 Features          Document version: 14/03/06

 

IO Expansion Module

IO-PT400, IO-PT4K
Two new modules offer 4 PT inputs (alpha): I/O-PT400 supports PT100 & NI100; I/O-PT4K supports PT1000 & NI1000

New modem support

Now supports Siemens TC65 modem

Entering Information mode control

The time that the <i> key must be held to enter Information Mode can be modified (3-20 seconds) via SI 178.
Entering 0 disables Information mode.

Information Mode SB 54

SB54 is ON when the <i> key is pressed, even when data is being entered into a Keypad entry Variable, and even if Information mode is disabled via SI 178=0

MODBUS

Improved performance at baud rates slower than 4800

 

 

U90 Ladder 5.09      Document version: 18/01/07

 

PID –Improved Algorithm (M91 only)

SB 109 switches between the old and new improved algorithm.

PID - Internal Auto-tune (M91 only)

M91 controllers using OS V3.72 (B08) or later now feature PID Internal Auto-tune via SBs. Requires SB 109 ON.

 

U90 Ladder 5.09      Document version: 20/08/06

 

M90 PID Internal Auto-tune

M91 controllers may now be easily tuned via SBs. Each PID loop is linked to two SBs, one to activate auto-tune, and one that signals when the process is complete. Check the new sample application: Help> Sample U90 Projects>PID M91 Auto-tune.U90.

 

U90 Ladder 5.07      Document version: 20/08/06

 

 

New translation files for Polish and Hungarian

New hardware model M91-2-RA22

New hardware expansion unit I/O PT4X

 

 

U90 Ladder 5.06

Document version: 24/07/06

 

New Controller models

Now supported in Hardware Configuration.

JZ10-11-R31
16 Digital, 2 Analog/Digital, 2 Analog Inputs, 11 Relay Outputs.

JZ10-11-T40
16 Digital, 2 Analog/Digital, 2 Analog Inputs, 20 Transistor Outputs.

M91-2-RA22

12 digital inputs, including high-speed counter/shaft encoder inputs,
2 analog inputs, 2 temperature measurement inputs, I/O expansion and RS232/485 ports.

Jazz Cloner support

In Jazz OPLCs, Information Mode now supports the Jazz Program Cloner. Full details are in the Jazz User Guide.

 

 

U90 Ladder 5.05

Document version: 08/06/06

 

Certain minor issues relating to support for the new Jazz series were fixed in the new version

 

 

U90 Ladder 5.00

Document version: 19/03/06

 

New Controller models

Jazz™ OPLC™
A new OPLC series that is now supported in Hardware Configuration.

M92-1-R34

This new M91 model runs off 24VDC, and offers 22pnp/npn digital inputs, including 3 high-speed counter/shaft encoder inputs, 2 analog inputs, 12 relay outputs, I/O expansion and RS232/485 ports.

New Features

Drum
The Drum Sequencer utility simulates a mechanical drum sequencer. Drum instructions are best suited for repetitive processes that consist of a finite number of steps.

Immediate Outputs

The M91-2-T38 now supports Immediate Set/Reset for outputs O 0, O 1, O 10, O 12, O 13, O 14, and O 15.

New I/O module support

IO-DI8ACH
New I/O expansion module, offers eight 110/220VAC inputs

Display Languages

If your PLC model is 'multilingual' you can type and display a number of languages on the controller's LCD. When you install U90 Ladder, the Display Settings box opens, enabling you to determine a default language for the HMI Displays. After installation, you can change the PLC Display Language at any time.

Modems

Modem Services, on the Controller menu, replaces PC Modem Configuration.
Modem Services enable you to initialize supported modems for both PC and PLC-side modems, via a 'Prepare Modem' procedure.

Database

Read/Write 1024 integers from U90 Ladder.

General Features

8 Watch folders enable you to monitor groups of operands.
Find & Replace now searches through Variables, Hardware Configuration, PID and SMS Configurations.
New Utility: Find Text in Comment.
Summary: Operands Not Referenced in Project.

 

 

U90 Ladder 4.01

Document version: 05/12/05

Bulgarian is now available from the View>Language menu.


 

U90 Ladder 4.00

Document version: 22/ 11/ 05

U90 Ladder Hardware Configuration

M91-2-R34
Runs off 24VDC, offers 22pnp/npn digital inputs, including 3 high-speed counter/shaft encoder inputs, 2 analog inputs, 12 relay outputs, I/O expansion and RS232/485 ports.

IO-DI8ACH (soon to be released)

Display Languages

If your PLC model is 'multilingual' you can type and display supported languages, according to the selected default language. When you install U90 Ladder, the Display Settings box opens, enabling you to determine a default language for the HMI Displays. After installation, you can change the default language at any time.

Modems

Modem Services, on the Controller menu, replaces PC Modem Configuration.
Modem Services enable you to initialize supported modems for both PC and PLC-side modems, via a 'Prepare Modem' procedure.
PLC Phone Book now supports the '+' (plus) sign as well as the ',' (comma) symbol.

Database

Read/Write 1000 integers from U90 Ladder.

Ladder: New Features

• Import/Export Nets
• Bookmarks
• Import/Export Operand Descriptions
• Rise/Fall Summary
• Delete All Comments
• Get Next Unused Operand when addressing elements

General Features

• Find & Replace now searches through Variables, Hardware Configuration,   PID and SMS Configurations.
• New Utility: Find Text in Comment.
  Summary: Operands Not Referenced in Project.


 

U90 Ladder V3.81

Document version: 22/ 06/ 04

PID Server:
Auto-tune PID loops

The PID Server PC utility enables you to auto-tune PID loops for both the Vision and M90/91 controller series. Although it is installed as part of the VisiLogic/U90 Setup, PID Server runs independently of other Unitronics software.
PID Server tunes a PID loop by temporarily disabling the PLC's PID function, and tuning the loop while the PC controls the PID output. The new utility is located on the Tools menu in both VisiLogic and U90Ladder


 

MODBUS
New M91 feature

MODBUS enables you to establish master-slave communications with any connected device that supports the MODBUS protocol, including SCADA systems. Any controller in the network may function as either master or slave using any of the controller's existing COM Ports. Unitronics currently supports RTU (binary) transmission mode.

PID Function
Last received

The PID function has been modified:
Negative Slope control has been added.
The Deadband parameter has been removed.
Please note that, in existing applications, the changes may require you to modify the P, I, and D parameters.

SMS number

New SIs, 188 to 192, now store the number of the last SMS received by the controller.

 

U90 Ladder V3.65 Document version: 16/ 02/ 04


 

O/S 360 B3

 

U90 Ladder V3.64 Document version: 18/ 01/ 04


 

Downloading Values to
the M90 Database

Download values to the M90 Database, by defining regions of integers in the database, entering values, and downloading. Note that you can also copy and paste values to from other applications, such as Excel.
These values can also be included in a .d90 download file.

Timer resolution
display

A Timer Resolution field has been added in the Timer Preset window; note that this field is read- only. The resolution is a function of the Timer Preset Value.

 

U90 Ladder V3.63


 

Bug fix- Variables

51- 64 could not be assigned descriptions.

 

U90 Ladder V3.62


 

Fast Outputs support

M91- 2- TC2

Display Fix

In the HMI Editor, some of the Jump conditions could not be viewed at a resolution of 600x800 (2- line models only); this has been fixed.

 

 

U90 Ladder V3.61


 

Supports new
M91 model

Supports M91- 2- R6C (2- line text display)

 

 

U90 Ladder 3.60 Version changes


 

Support for 2- line
M91 model

Supports M91- 2- T38, the first 2- line text display model. In addition to more
text, up to 8 variables can be displayed on the LCD. When this model is
selected, the HMI editor will show the larger display screen. Additional
features include 36k memory, 64 HMI variables.

New controller
support

M91- 19- 4TC2

New I/ O module
support

IO- ATC8, 8 Thermocouple / Analog inputs

New Special
Functions

Indirect GSM PIN Code and Calculating 'long' integers (M91 only)

New System
Operands

SB 35- 38 Keypad entry completed, support the 4 additional variables that
may be show on the LCD of 2- line display models.
SI 187, Number of SMS messages to be deleted, enables you to delete up
to 30 SMS messages.

Undo

Added to U90Ladder features